Gold Member Since 2014
Audited Supplier
Big Pawer Electrical Technology Xiangyang Inc. Co., Ltd.

Hv, Shunt Capacitor, Automation manufacturer / supplier in China, offering Tbba Series Hv Shunt Capacitor Device (Automation), Tcs Series Voltage Reduce and Compensation Solid Soft Starter, Mv Ydq Series Liquid Resistor Rotor Soft Starter and so on.

(/ )

Supplier Homepage Product Specialized Electrical Equipment Tbba Series Hv Shunt Capacitor Device (Automation)

Tbba Series Hv Shunt Capacitor Device (Automation)

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Shanghai, China
Production Capacity: 1000 Sets Per Year
Payment Terms: L/C, T/T, Western Union, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: TBBA
  • Protection: Corrosion Resistance
  • Housing: Steel Plate
  • Transport Package: Wooden Case
  • Origin: Xiangyang, Hubei Province, China
  • Certification: ISO9001, CCC
  • Installation: Vertical
  • Trademark: Big pawer
  • Specification: CE, ISO90001
  • HS Code: 85321000
Product Description
TBB general introduction short
 
1. General 
 
1.1 Brief introduction
TBB series type high voltage parallel capacitor device has indoor cabinet type and outdoor frame type structure. With its reasonable design and layout it has good kinetic and heat stability and capacitor protection functions. According to the system condition of users, electric reactor with different reactance rate can be equipped to suppress harmonic and switching in rush current, to restrict the instant rush current generated when the capacitor is put into operation to less than 20 times rated current of capacitor bank. 
 
 
1.2 Application range
TBB series type high voltage parallel capacitor device is suitable for 50Hz power distribution system with rated voltage 6kV/10kV/35kV as compensation device of system reactive power. 
 
1.3 Technical feature
The product can adjust adjust the power factor of power distribution system to maximum, adjust the grid voltage to reduce the loss of power distribution system and transformer, further to improve the power quality of power grid.
 
2. Technical parameter
 
Diagrams 1, 2, 3 are typical primary system diagram and outside diagram; Tables 1, 2, 3 are corresponding type, specifications, main parameters and external dimensions.
External and installation dimensions are subject to detailed design.
 
 Tbba Series Hv Shunt Capacitor Device (Automation)Tbba Series Hv Shunt Capacitor Device (Automation)
Diagram 1(scheme 1): primary system and outside diagram (HV capacitor switch cabinet chosen by user)

 Tbba Series Hv Shunt Capacitor Device (Automation)
Tbba Series Hv Shunt Capacitor Device (Automation) 
 
Diagram 2(scheme 2): primary system diagram and outside diagram(HV capacitor switch cabinet chosen by user)
 
 Tbba Series Hv Shunt Capacitor Device (Automation)
 
Diagram 3(scheme 3): primary system diagram
 
 
Table 1 (scheme 1)
TypeRated voltage (kv)Capacitor bank rated capacity
(kvar)
Device rated current
(A)
Wiring typeExternal dimensions
Width (1200mm+A)×depth×height (mm)
TBB6-900/300-AK6900(3×300)78.7Y2400×1600×2650
TBB6-1000/334-AK61000(3×334)87.4Y2400×1600×2650
TBB6-1200/200-AK61200(6×200)105Y2400×1600×2650
TBB6-1500/250-AK61500(6×250)131Y2400×1600×2650
TBB6-1800/300-AK61800(6×300)157.5Y2400×1600×2650
TBB6-2000/334-AK62000(6×334)175Y2400×1600×2650
TBB10-900/300-AK10900(3×300)47Y2400×1600×2650
TBB10-1000/334-AK101000(3×334)52.5Y2400×1600×2650
TBB10-1200/400-AK101200(3×400)63Y2400×1600×2650
TBB10-1500/500-AK101500(3×500)78.7Y2400×1600×2650
TBB10-1800/300-AK101800(6×300)94.5Y2400×1600×2650
TBB10-2000/334-AK102000(6×334)105Y2400×1600×2650
TBB10-2400/400-AK102400(6×400)126Y2400×1600×2650
TBB10-2700/450-AK102700(6×450)141.7Y2400×1600×2650
TBB10-3000/500-AK103000(6×500)157.5Y2400×1600×2650
 
Table 2(scheme 2)
TypeRated voltage (kv)Capacitor bank rated capacity
(kvar)
Device rated current
(A)
Wiring typeExternal dimensions
Width×depth×height (mm)
TBB6-300/100-AK6300(3×100)26Y1200×1600×2650
TBB6-450/150-AK6450(3×150)39.4Y1200×1600×2650
TBB6-600/200-AK6600(3×200)52.5Y1200×1600×2650
TBB6-750/250-AK6750(3×250)65.6Y1200×1600×2650
TBB6-900/300-AK6900(3×300)78.7Y1200×1600×2650
TBB6-1000/334-AK61000(3×334)87.5Y1200×1600×2650
TBB10-300/100-AK10300(3×100)15.7Y1200×1600×2650
TBB10-450/150-AK10450(3×150)23.6Y1200×1600×2650
TBB10-600/200-AK10600(3×200)31.5Y1200×1600×2650
TBB10-750/250-AK10750(3×250)39.4Y1200×1600×2650
TBB10-900/300-AK10900(3×300)47Y1200×1600×2650
TBB10-1000/334-AK101000(3×334)52.5Y1200×1600×2650
TBB10-1200/400-AK101200(3×400)63Y1200×1600×2650
TBB10-1350/450-AK101350(3×450)71Y1200×1600×2650
TBB10-1500/500-AK101500(3×500)78.7Y1200×1600×2650
 
Table 3(scheme 3)
TypeRated voltage (kv)Capacitor bank rated capacity
(kvar)
Device rated current
(A)
Wiring typeExternal dimensions
Width (1200mm+A)×depth×height (mm)
TBB6-1800/300-BL61800(6×300)157.5Y-Y2400×1600×2650
TBB6-2000/334-BL62000(6×334)175Y-Y2400×1600×2650
TBB6-2400/200-BL62400(12×200)210Y-Y3600×1600×2650
TBB6-3000/250-BL63000(12×250)262.4Y-Y3600×1600×2650
TBB6-3600/300-BL63600(12×300)315Y-Y3600×1600×2650
TBB6-4000/334-BL64000(12×334)350Y-Y3600×1600×2650
TBB6-4500/250-BL64500(18×250)393.6Y-Y4800×1600×2650
TBB6-5400/300-BL65400(18×300)472.4Y-Y4800×1600×2650
TBB6-6000/334-BL66000(18×334)525Y-Y4800×1600×2650
TBB10-1800/300-BL101800(6×300)95Y-Y2400×1600×2650
TBB10-2000/334-BL102000(6×334)105Y-Y2400×1600×2650
TBB10-2400/400-BL102400(6×400)126Y-Y2400×1600×2650
TBB10-3000/500-BL103000(6×500)157.5Y-Y2400×1600×2650
TBB10-3600/300-BL103600(12×300)189Y-Y3600×1600×2650
TBB10-4000/334-BL104000(12×334)210Y-Y3600×1600×2650
TBB10-4800/400-BL104800(12×400)252Y-Y3600×1600×2650
TBB10-5400/450-BL105400(12×450)283Y-Y3600×1600×2650
TBB10-6000/500-BL106000(12×500)315Y-Y3600×1600×2650
TBB10-7200/400-BL107200(18×400)378Y-Y4800×1600×2650
TBB10-8100/450-BL108100(18×450)425Y-Y4800×1600×2650
TBB10-9000/500-BL109000(18×500)472Y-Y4800×1600×2650
 
 
3. Service conditions
 
There are indoor and outdoor types of the product;
Ambient temperature -25ºC~+45ºC;
Relative humidity maximum 85%;
Altitude maximum 1000m;
Installation place should avoid strenuous vibration;
The maximum horizontal gradient of installation should be 5 degree;
No harmful gas, vapor, electric or explosive gas and other dangerous materials;
Remark: If above-mentioned requirements can not be met, special design is needed.
 
 
4. Type explanation

Tbba Series Hv Shunt Capacitor Device (Automation)
 
Installation: W-outdoor
Protection mode: K-open delta, C-voltage differential, Q-bridge differential,    L-neutral point imbalance
Primary wiring type: A-single star, B-double star
Single capacitor capacity kVar
Total capacity kVar
Device rated voltage kV
Parallel capacitor compensation
Complete set
 
5. Ordering instructions
Following documents should be provided to manufacturer before ordering
Primary wiring diagram, floor diagram, layout diagram.
Type, specifications, voltage level, capacity, scheme type, incoming type of product.
Please specify if following components are required: serial connected reactor, zinc oxide arrester, discharge coil, earthing knife switch, complete set cabinet, enclosure and others.
Customized cabinet dimensions and color.
Other special technical requirements.
 
 
Send your message to this supplier
Avatar
Mr. Wang Jing
Bussinessman
*From:
To: Mr. Wang Jing
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

Find Similar Products By Category