Basic Info
  • Model NO.: MSS
  • Structure: Modularized
  • Signal: Discrete
  • Certification: CCC, ISO: 9001
  • Customized: Non-Customized
  • Trademark: Big Pawer
  • Origin: Hubei Province, China
  • Task: Soft Start
  • Mathematical Model: Non-Linear
  • Function: Automatic Control
  • Condition: New
  • Material: Stainless Steel
  • Transport Package: Wooden Box
  • HS Code: 8535900090
Product Description
1. Product introduction
 
1.1 General
 
MSS HV modularized solid soft starter which integrates thyristor components, bypass vacuum switch, trigger control system. This product has compact structure and independent soft start function.
 
Its working principle is to control the value of output voltage by adjusting the triggering angle of thyristor, and to meet various current and voltage requirements during motor start process. During starting, MSS HV modularized soft starter will increase the terminal voltage of motor according to the preset starting curve, to make the motor smoothly accelerate, in order to reduce the electrical and mechanical impact to power grid, motor itself and motor loads. After the motor reaches normal speed, the bypass switch be closed which means the starting process is finished. MSS HV modularized soft starter will provide running protection to the motor. 
 
The structure of this starter is similar to HV vacuum circuit breaker and it fits the KYN28 cabinet perfectly. MSS can upgrad the traditional HV switch cabinet to a device with both switch and soft start functions. Its performance can completely meet users' requirements.
 
1.2 Range of application
 
MSS HV modularized solid soft starter is applicable for voltage reduction soft start of various large and medium HV motors.
 
Applicable motor range:
Voltage: 3.6/7.2/12KV
Power: 200~2000KW
Frequency: 50HZ/60HZ ± 2HZ
Phase sequence: works if input and output phase sequence is identical
Motor type: 3 phase HV AC motor
 
 
1.3 Features
 
StructureSoft start modulePatented thyristor serial-parallel crimp connection technology, integrated together with vacuum switch components to make compact structure.
Power source moduleUnique switch closing control circuit, reliable and small.
Control moduleHighly integrated main control panel with various interface drew out by standard VS1 aviation plug, convenient for wiring and maintenance.
ElectricalReliable control systemControl system has passed strict EMC electromagnetic compatibility test which shows the strong anti electro-magnetic interference performance.
Various control planSmoothly start the motor by measuring starting current and negative feedback control the triggering angle of thyristors. It has various start control mode with optional coast stop or soft stop function.
Touch screen displayComprehensive display content, convenient to operate
Customized protection functionMultiple grade protection function, customized start and running protection settings.
Low power consumption closing coilAdopting patented power source control technology, compared to traditional contactor it has removed divider resistance, significantly reduced power consumption.
Advanced triggering systemAdopting patented triggering technology, good pulse consistency and insulation
System communication functionRS-485 communication port integrated (communication protocol Modbus and Porfibtjs optional). Direct connection to superior PC through this port can realize remote control and signaling functions
 
2. Technical parameters
2.1 working principle
 
The soft starter will trigger thyristor according to the measured voltage signal and preset parameters, the output voltage will gradually increase in order to decrease the terminal voltage and starting current during motor start, to smoothly accelerate the motor to its rated speed. If the measured current is decreasing it will automatically switch to bypass to realize the soft start of large and medium motors. 
Following is the principle diagram of modularized soft starter:
 
Mss Soft Starter Module for Switch Cabinet
 
To equip MSS, the soft starter device can be designed according to following diagram:
 
 Mss Soft Starter Module for Switch Cabinet
Typical scheme 1: operating cabinet + start cabinet
 
 Mss Soft Starter Module for Switch Cabinet
Typical scheme 2: 2-in-1 single cabinet
 
Scheme sketches:
 
 Mss Soft Starter Module for Switch Cabinet
                    Typical scheme 1                          Typical scheme 2
 
Scheme 1: two standard KYN28 (800 type) cabinets, connected with other switch cabinets, large room for convenient wiring and maintenance.
Scheme 2: one standard KYN28 (800 type) cabinets, connected with other switch cabinets, compact structure, saving a cabinet.
 
2.2 Main technical parameters
 
Rated voltage6kV,10kV
Bypass rated current630A
Applicable motor current0~100A
Applicable motor powerFor 10kV below 1600kW/ for other rated voltage depends on motor current
Motor type3 phase squirrel cage or winding motor, asynchronously started synchronous motor
Rated working frequency50HZ/60HZ±2HZ
Phase sequenceWorking in any phase sequence allowed
Control powerAC220V ± 10%
Operation panel480*272 touch screen
Power frequency withstand voltage25kV (phase to ground)
Cooling methodForced air cooling
Starting timesAmbient temperature 25ºC and rated current below 100A, starting times≤4 times per hour, minimum starting interval 10 minutes
Starting protectionOver current, over voltage, under voltage, current imbalance, starting over time protections; bypass vacuum switch closing fault detect;
Running protectionOver current, over voltage, under voltage, current imbalance, starting over time protections; bypass vacuum switch closing fault detect;
Start methodVoltage ramp start, constant time start, current limit start, soft stop
Soft start time0~100 seconds adjustable
Soft stop time0~60 seconds adjustable
Output voltage20%~100% adjustable (by change triggering time)
Current limit magnification1Ie~5Ie adjustable
Communication portRS-485 communication port, by default support Modbus protocol, Profibus optional
Ambient temperatureWorking:-15ºC~+50ºC, storage:-25ºC~+70ºC
Ambient humidity≤95% without condensation
Altitude≤2000 m
 
 
 
2.3 Working condition
 
Upper limit of ambient temperature is +40ºC (24 hours average 35ºC), and lower limit is 1-5ºC.
The relative humidity is no more than 95 percent. The height above sea level is no more than 2000m.
It should be placed on an indoor place without obvious shake and impact, without fire and explosive dangers and the vertical gradient is no more than 5º.
There must be no conductive dust and corrosive gas.
 
Special environment:
In case the soft starter will be equipped in special environment, user should communicate with manufacturer and reach an agreement. Normally there are following possible special environments:
If the altitude is over 1000m, the external insulation will decrease, user should ask the manufacturer if the product is applicable. If not applicable the user can choose the special products which can meet the requirements and provided by manufacturer.
If the ambient temperature is too high, the product should run with less load, the continuous start times is reduced or an additional forced cooling fan should be equipped.
If the starter is used in high humidity or big temperature difference site, normally additional protective device should be equipped (heaters e.g.) to avoid condensation.
 
2.4 Type explanation

 Mss Soft Starter Module for Switch Cabinet
Specifications:
Table 1: type and applicable motor power
 
TypeRated voltage
kV
Applicable motor power kW
MSS1-500/1010500
MSS1-710/1010710
MSS1-1000/10101000
MSS1-1250/10101250
MSS1-1600/10101600
MSS1-500/66500
MSS1-710/66710
MSS1-1000/661000
 
 
3. Order instructions
3.1 Motor type, rated power, rated voltage, rated current, locked-rotor current multiples, starting torque multiples, motor and load moment of inertia, bus bar capacity of short circuit, variation curve of load drag torque;
3.2 Primary schematic diagram, cabinets layout diagram, power distribution room layout diagram, low voltage power source and so on.
For special requirements please communicate with manufacturer.
 