Gold Member Since 2014
Audited Supplier
Big Pawer Electrical Technology Xiangyang Inc. Co., Ltd.

Svg, Static Var Generator, Power System manufacturer / supplier in China, offering Dlsvg Series of Static Var Generator, Mv Ydq Series Liquid Resistor Rotor Soft Starter, Htr Series High Voltage Thermal Resistor Soft Starter and so on.

(/ )

Supplier Homepage Product Specialized Electrical Equipment Dlsvg Series of Static Var Generator

Dlsvg Series of Static Var Generator

FOB Price: Get Latest Price
Min. Order: 1 Piece
Port: Shanghai, China
Production Capacity: 1000 Sets Per Year
Payment Terms: L/C, T/T, Western Union, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: SVG
  • Protection: Corrosion Resistance
  • Housing: Steel Plate
  • Measurement: in Following Diagram
  • Transport Package: Wooden Case
  • Origin: Xiangyang, Hubei Province, China
  • Certification: ISO9001, CCC
  • Installation: Vertical
  • Cabinet Color: Customizable
  • Trademark: Big pawer
  • Specification: CE, ISO9001
  • HS Code: 8537109090
Product Description
DLSVG general introduction
 
1.Product introduction
 
1.1 general
Nowadays static var generator is an important method of reactive compensation in power grid. Its fundamental principle is to detect reactive current from power grid or compensation object and generate compensating current which is opposite to the reactive current, to eliminate the reactive current and improve power factor. SVG will not be affected by power grid impedance. It adopts dynamic tracking to compensate reactive current. Its response time is short. Our SVG adopts multilevel power units ----- topological structure, integrated compensates various different loads. That is to say, it consider reactive, harmonics and negative sequence as one "distorted waveform" component. By this way it can not only dynamically absorb reactive power, improve power factor, but also absorb random harmonics. At present, SVG is an ideal device to avoid power grid "pollution", improve power quality and save energy.
 
1.2 application range
Typical application conditions are as following:
1.2.1 regional power grid
1.2.2 wind power plant
1.2.3 rolling mill
1.2.4 arc furnace
 
2.Technical features:
SVG can automatically adjust the value and property (capacitive or sensibility) of its output reactive power. Therefore, SVG can be regarded as capacitor or reactor whose value can be continuously adjusted.
SVG is the most advanced dynamic reactive compensation technology. It does not adopt large capacitor and reactor components, and realizes the switch of reactive power by high-frequency switch of large power electrical components. Its technical features are following:
 
2.1 quick response
Response time of auto switching capacitor bank is several seconds and SVC approximately 20~100ms; the compensation response time of SVG device can be within 5ms. SVG can suppress voltage flicker and drop effectively and realize true dynamic compensation.
2.2 continuous compensation. The power factor can be close to 1.0.
2.3 no harmonic amplification. It can be used in power distribution system of frequency converter, induction heating power supply, controllable resistance furnace and rectifier power supply of electrolytic plating.
2.4 can generate both inductive and capacitive reactive power. It is applicable for both conditions, to improve the compensation effect and lower line loss.
2.5 output reactive will not be effected by power grid voltage. The reactive power of capacitor compensation device or SVC is in direct proportion to the square of voltage. When the voltage is low, reactive power output will significantly decrease. Normally the use ratio of capacitor compensation device is only 60~80%, meanwhile SVG is 100%.
2.6 can compensate harmonic and reactive power at the same time if necessary.
2.7 adopts H bridge cascade multilevel circuit structure, directly insert 6kV, 10kV, 27.5KV and 35kV. Besides it adopts N+1 or N+2 redundant structure. If one H bridge chain link is damaged, the device can still run with full load. Its reliability is very high.
2.8 SVG is connected to power grid and adopts LCL structure. Comparing to traditional single reactor access to power grid, SVG has following advances: applicable to any site power system impedance without resonance, ensures the reliability and safety of device; The higher harmonics generated y IGBY high frequency switch will not be ejected to power grid when SVG is working; SVG has better reactive compensation and harmonic suppression effect.
2.9 the control system of SVG adopts FPGA. The maximum clock rate of FPGA can be 200Mhz according to requirements. It concludes 84 hardware DSP digital signal processor units, 1.8 million logical gates. It is very good at digital signal processing. Therefore it can adopt more advanced algorithm to improve the performance of SVG.
2.10 new type control algorithm and mudulation mode, together with super computing ability enhances the harmonic filtration ability of SVG device. It can filter all harmonics within 30 times with over 97% filtration efficiency.
2.11 high reliability: design of SVG follows HV national mandatory standard. HV main circuits and control circuits are connected by optic fiber which is safe and reliable.
2.12 perfect protection and fault alarm design including system and power units protection, fault auto record and memory functions which can automatically record the protection action type and action time to help the technicians locate the fault and analyze the cause.
2. 13 high flexibility:SVG can be control by PLC on site. Its control mode can be changed by set parameters via human-computer interface. Various standard communication protocols available for communication with central control system.
 
3. Technical parameters
3.1working principle
SVG dynamic reactive power compensation device adopts multilevel power units cascade topological structure, via parallel connection with system, real-time detect harmonic and reactive power component of load, with PWM conversion technology, injects current which is same in value and opposite in direction to harmonic and reactive power components, into power distribution system, to realize harmonic suppression and dynamic reactive power compensation functions. 
 
Dlsvg Series of Static Var Generatorright side: user load
 
Diagram 3.1 SVG functional block diagram
 
 Dlsvg Series of Static Var Generator
Diagram 3.2 schematic diagram of SVG main circuits
Running modeWaveform and phasor diagramdescription
No load running modeDlsvg Series of Static Var GeneratorUI = Us,IL = 0,SVG does not absorb and generate reactive power
Capacitive running modeDlsvg Series of Static Var GeneratorUI > Us,IL  is advanced current, its amplitude can continuously controlled by adjusting UI,to continuously control reactive power generated by SVG
Inductive running modeDlsvg Series of Static Var GeneratorUI < Us,IL is hysteresis current. At this time the reactive power which is absorbed by SVG can be continuously controlled.
 
Diagram 3.3 three running mode of SVG

 
3.2 components of DLSVG
 
The DLSVG device consists of control cabinet, power cabinet, start cabinet. The isolation switch is connected with power grid.
 
 
3.3 control and protection system functions
3.3.1 As the modulation process is non-linear, there is error with calculation parameters, and there are shift and drift factors in whole system, the device must adopt close-loop control to reach the control accuracy and response speed requirements.
 
3.3.2 protection functions
 
System over current protection
System over voltage protection
System under voltage protection
Unit over voltage protection
Unit over heat protection
Unit short circuit protection
Unit communication anomaly protection
Device door open alarm
 
main technical parameters
 
ItemStandardRemark
Using standardQ/XDL 18-2015 
Installation placeIndoor cabinet type 
Topological structurePower units parallel connected to PWM voltage source 
Power grid voltage(+10%-20%) rated voltage, frequency 50Hz(±5%) 
Compensation harmonic range2~25 times 
Response time<5ms 
Switch frequency  6kHz(average) 
Active power loss<5% 
Reliability standard(mean time between failures)25000 hours        
Power unit control signal connection methodOptic fiber cable 
Noise grade<65dBA(1 meter)
Protection grade≥IP20 
Cooling method Forced air cooling 
Operation modeTouch screen 
Interface languageFull Chinese 
EarthingEarthing resistance <1Ω 
 
Type explanation 

Dlsvg Series of Static Var Generator
 
TypeVoltage gradeRated capacityExternal dimensions
DLSVG-2000/066kV2000kvr2400*2300*1300
DLSVG-4000/066kV4000kvr4800*2300*1300
DLSVG-5000/066kV5000kvr4800*2300*1300
DLSVG-1000/1010kV1000kvr2400*2300*1300
DLSVG-2000/1010kV2000kvr2400*2300*1300
DLSVG-4000/1010kV4000kvr4800*2300*1300
DLSVG-5000/1010kV5000Kvr4800*2300*1300
DLSVG-8000/1010kV8000kvr7800*2300*1200
DLSVG-10000/1010kV10000kvr7800*2300*1200
DLSVG-15000/1010kV15000kvr7800*2300*1200
 
Ordering instructions
 
For better reactive power compensation and filtration effect, the rated capacity should be determined according to actual power grid compensation conditions.
Therefore user should provide power grid parameters, system running voltage, current, active power, reactive power, power factor, harmonic components information. Big Pawer can take power quality monitors and other devices to site for help if necessary.